Intelligent Control With High Efficiency Fan Dry Air Cooler For Server Room Cooling

Guangdong Longer Leader Energy Equipment Co.,Ltd.
Contact Now

Intelligent Control With High Efficiency Fan Dry Air Cooler For Server Room Cooling

Brand Name : Longer Leader

Model Number : LDDC-0103V-3R-AC710

Certification : ISO9001, CQC

Place of Origin : China

MOQ : 1 set

Price : Negotiable

Payment Terms : T/T

Supply Ability : 30~50 sets / Month

Delivery Time : 30 days

Packaging Details : Export standard paper carton or wooden case

Product name : Data Center products

Installation : Floor standing

Heat capacity : 104KW

Warranty : 1 year

Air flow : 42000m³/h

Brand name : Longer leader

Video : Provided

After-sales Service Provided : Online support

Type : dry cooling tower

Contact Now

Intelligent Control With High Efficiency Fan Dry Cooler For Server Room Cooling

Quick Model Selection for Typical Units ( with AC fans)
Model Air flow(m3/h) Heat capacity(kw) Water flow(l/s) Fan size(mm) Fan unit(pcs) Motor power(kw) Unit size(mm):L*W*H
LDDC-0101P-3R-AC630 8300 24.87 1.21 630 1 0.74 1000*980*880
LDDC-0101P-4R-AC630 8800 29.26 1.44 630 1 0.74 1000*980*900
LDDC-0101P-3R-AC710 11000 32.47 1.57 710 1 1.23 1150*1100*880
LDDC-0101P-4R-AC710 11500 38.02 1.86 710 1 1.23 1150*1100*900
LDDC-0102P-3R-AC630 16600 50.36 2.43 630 2 1.48 1950*980*880
LDDC-0102P-4R-AC630 17600 58.53 2.86 630 2 1.48 1950*980*900
LDDC-0102P-3R-AC710 22000 66.94 3.23 710 2 2.46 2250*1100*880
LDDC-0102P-4R-AC710 23000 76.24 3.71 710 2 2.46 2250*1100*900
LDDC-0103P-3R-AC630 24900 75.65 3.66 630 3 2.22 2900*980*880
LDDC-0103P-4R-AC630 26400 86.33 4.2 630 3 2.22 2900*980*900
LDDC-0103P-3R-AC710 33000 99.86 4.82 710 3 3.69 3350*1100*880
LDDC-0103P-3R-AC710 34500 114.11 5.54 710 3 3.69 3350*1100*900
LDDC-0104P-3R-AC630 33200 102.35 4.95 630 4 2.96 3850*980*888
LDDC-0104P-4R-AC630 35200 116.53 5.68 630 4 2.96 3850*980*900
LDDC-0104P-3R-AC710 44000 134.91 6.52 710 4 4.92 4450*1100*880
LDDC-0104P-4R-AC710 46000 153.86 7.48 710 4 4.92 4450*1100*900

Note:
The above working conditions are based on 42℃/47℃ inlet/outlet temperature, the medium is pure water,
ainlet air temperature is 30℃.
If the actual working conditions are different from the reference working conditions, please contact the relevant
HVAC engineers for selection.
Product Description

A dry coolers is the same as air cooled condensing unit but utilizes some liquid solutions, such as water, ethylene glycol/water, to transfer hear being replace of refrigerant and compressor.

A dry cooler system are often see in Data centers where excess heat needs to be removed but low levels of humidity are not required.

A significant feature of dry cooler system is that no liquid evaporation takes place, which eliminates the need for make-up water.

As closed-circuit systems, dry coolers deliver several benefits compared to wet cooling towers, including lower initial costs and maintenance, improved system reliability and increased uptime.

Dry coolers can help to make a building working more efficiently. Though this system is not known for saving energy, it can be used as a condensing unit for a heat recovery chiller. When a heat recovery chiller supplements a chilled water system, there will be ask for a system to remove excess heat. This is the perfect application for a dry cooler, which serves as a condensing unit or cooling tower.

.

Why choose dry cooler replace of cooling tower?

No water consumption, eco-friendly - Dry Coolers do not require water. Instead, air is blown over a heat exchanger in order to remove the heat from the liquid in the system..
Easy maintainence - Dry Coolers are easier to maintain because the water is not exposed to air (closed loop) and they do not require water testing . Cooling Towers are susceptible to degradation through fouling (getting clogged up), scaling (water-deposit build-ups) corrosion (gradual breakdown due to the environment), and require testing for the prevention of Legionnaire’s disease.

Robust structure

Common dry cooler designs are flatbed units with either vertical or horizontal airflow direction or V-shaped units with one or two rows of axial fans with lateral air suction and discharge from the top.

Horizontal Airflow Direction

Intelligent Control With High Efficiency Fan Dry Air Cooler For Server Room Cooling

Intelligent Control With High Efficiency Fan Dry Air Cooler For Server Room Cooling

Vertical Airflow Direction

Intelligent Control With High Efficiency Fan Dry Air Cooler For Server Room Cooling

Intelligent Control With High Efficiency Fan Dry Air Cooler For Server Room Cooling

Application

Dry coolers are often used in applications where water is scarce or where the use of water is prohibited due to environmental regulations. They are also commonly used in industrial processes, such as power generation and chemical processing, where cooling is required to maintain optimal operating conditions.

Data center, office building, hospitals, industrial / process system, heat transfer / recuperation, power generation and induction cooling.

Longer Leader Advantages

no water consumption, easy maintenance, eco-friendly.


Product Tags:

high efficiency air dry cooler

      

high efficiency dry air cooler

      
China Intelligent Control With High Efficiency Fan Dry Air Cooler For Server Room Cooling wholesale

Intelligent Control With High Efficiency Fan Dry Air Cooler For Server Room Cooling Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangdong Longer Leader Energy Equipment Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)